Start performance indicator
The action is used to start calculating performance indicators defined in the process. Performance indicators are defined in the process settings, in the Definitions > Performance indicators section. The action can be embedded on any automation event — e.g. on entering a step, on leaving it, on a transition path, or on a menu button.
It should be used in conjunction with the Stop performance indicator action, which stops the indicator calculation.
Basic configuration
The Basic tab of the Properties panel contains settings shared by every action in an automation: the Active toggle, the Action type field, the Documentation field, the Use action template toggle (when enabled, the action takes its configuration from the selected action template defined in the process), the Execution condition section (decides whether the action always runs or only when a custom rule is met), and the Runtime error handling section (the message and numeric error code returned when the action fails). Since these settings are not unique to the Start performance indicator action, they are described in detail in the Actions chapter.

Advanced configuration
The Advanced tab contains 2 fields specific to this action: the indicator whose calculation is to be started and the operating mode.

1. Indicator
The Indicator field specifies the performance indicator whose calculation the action starts. Expanding the field displays a list of the performance indicators defined in the process, together with a search box. The field has no default value and is required. The indicator can only be selected from the list — it cannot be specified dynamically.
Indicators marked as archived cannot be selected in the configuration of newly created actions. An archived indicator is also not calculated, even if actions that start and stop its calculation are configured in the process.
2. Operating mode
The Operating mode field determines how the performance indicator calculation behaves when it is started up again.
The calculation of the same performance indicator can be started and stopped multiple times for one workflow instance.
3 operating modes are available:
- Start from zero (resets the counter) – the counter is set to zero and the counting begins (default option). Any previous value the counter may have had is lost.
- Continue counting (does not reset counter):
- if started for the first time, the counter begins at zero,
- if the counter already has some value (i.e. the calculation was not stopped but is being started again), this value is left as is and the counting continues,
- an indicator that was previously stopped continues counting from the value it was stopped at.
- Continue counting including the time since the counter stopped:
- if started for the first time, the counter begins at zero,
- if the counter already has some value (i.e. the calculation was not stopped but is being started again), this value is left as is and the counting continues,
- an indicator that was previously stopped continues counting from the value it was stopped at, plus the time that elapsed from when it was stopped until it was started again.
In the Continue counting including the time since the counter stopped mode, the time between being stopped and started again is calculated according to the operating mode configured for the indicator itself, and therefore may take into account calendar days or working days (hours). The indicator configuration is described in the Performance indicators chapter.